Hafenspitze / Hyatt Hotel Düsseldorf

Other in Düsseldorf

Applications Used

Lighting

Heating, Ventilation & Air conditioning (HVAC)

Security and Safety

Operation and Visualisation

Energy Management/Smart Metering

Other

Automation and Remote Access

Blind and Shutter Control

Project Details

Category Value
Project Category Other
Project Type Commercial
Year of Completion 2011
Project Size 5.000+
Number of KNX Devices Used 1.000+
KNX Transmission Media Twisted pair
Man Hours 501 – 1.000
Man Power 1 – 5

Featured in this project

Siemens AG
Gira Giersiepen GmbH & Co. KG
Elsner Elektronik GmbH

Detailed Description

Energy Efficiency

The usage of automated functions already save energy in every installation. Especially the usage of KNX has a lot of potential for further energy savings, which can contribute to a better environmental footprint. Be extending KNX to more functions and applications, energy savings of up to 60% can be realised. Thanks to the flexibility of KNX, these functions can easily be implemented in this installation

Innovation

Smart homes and buildings are always an upgrade in comparison to a conventional installation. Not only automated functions and a higher level of comfort contribute to a higher living standard, but also the possibility to be ready for coming innovations. Thanks to the usage of KNX, the door has been opened to integrate new innovative solutions, using the worldwide STANDARD for home and building control.

Applications Used

  • Lighting - Switching, Dimming, Light Scenes, Timed Control, Lighting Colour Control
  • Heating, Ventilation & Air conditioning (HVAC)
  • Security and Safety - Emergency Lighting, Supervision (e.g. Cameras)
  • Operation and Visualisation - Switches / Push Buttons, Touch Panels & Display Panels
  • Energy Management/Smart Metering
  • Other
  • Automation and Remote Access - Timed Functions, Logical Functions
  • Blind and Shutter Control - Individual Control, Group & Central Control, Preset Positioning, Automatic Programs, Wind and Rain Protection, Sun Tracing (interaction with HVAC / lighting)

Customers Description

Maximale Gebäudeeffizienz, sowie optimaler Nutzerkomfort sind für ein 5-Sterne-Hotel mit angrenzendem Bürokomplex natürlich absolut Pflicht. Herstellerunabhängig haben wir auf 16 Etagen in drei Gebäuden den höchstmöglichen Automatisierungsgrad mit sämtlichen Sicherheiten realisieren können. Hinzu kommen hochwertige Lichtszenen, die es ermöglichen eine konsistent hochwertige Beleuchtungsqualität umzusetzen. Es wurden nahezu 4000 Geräte verteilt auf 4 Bereiche verbaut mit internen logischen Abhängigkeiten.

Contact Information

Company Name CA Brachtendorf GmbH & Co KG
Company Email info@cab-ih.com
Company Website https://cab-ih.com/
Contact Name Clemens Augsut Brachtendorf
Contact Function System Integrator